Short Description:
1 BF FIRE PROT - 5012 AC, 6140 SF, SFR / 2 STORY
Expiration Date:
2/19/2019
Notes:
(4/23/2012 2:37 PM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(4/23/2012 2:37 PM JC)
(MFD)
1 BF FIRE PROT - 5012 AC, 6140 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
PARK PLACE ESTATES PH1
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | DICKSON, DAVID T & JAMI M | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
MAIL TO | DICKSON, DAVID T & JAMI M | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | wstory@metrotechelectric.com | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
FIRE CONTACT | RES COM FIRE SYSTEMS | (214)350-1755 | | P.O. BOX 630886 | IRVING, TX 75068 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/13/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
4/24/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/6/2018
| | 4/6/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/18/2017
| | 4/18/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/19/2016
| | 2/19/2016 | |
More Info
|
There are currently no reviews on this record.