Permit Info
Short Description:
1 BF FIRE PROT -5261 AC, 6504 SF, SFR / 2 STORY
Approved Date:
11/30/2017
Expiration Date:
11/19/2018
Notes:
(3/13/2012 12:55 PM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(3/13/2012 12:55 PM JC)
(MFD)
1 BF FIRE PROT -5261 AC, 6504 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #1B (CFR)
|
BF TESTER | SCOTT MASDON | (214)587-4616 | | 5068 AVERY LN | THE COLONY, TX 75056 |
OWNER | BORYNACK ZACHARY ALEXANDER & | ()- | STEPHANIE@SHADDOCKHOMES.COM | STACI RENEE BORYNACK | FRISCO, TX 75035-1226 |
MAIL TO | BORYNACK ZACHARY ALEXANDER & | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75035-1226 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | wstory@metrotechelectric.com | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/8/2015
|
BACK FLOW FORM REVIEW |
$25.00
|
12/14/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/30/2017
| | 11/30/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/1/2016
| | 12/1/2016 | |
More Info
|
BACKFLOW | APPROVED |
11/19/2015
| | 11/19/2015 | |
More Info
|
There are currently no reviews on this record.