Permit Info
Short Description:
1 BF FIRE PROT - 8634 AC, 11456 SF, SFR / 2 STORY
Expiration Date:
2/19/2019
Notes:
1 BF FIRE PROT - 8634 AC, 11456 SF, SFR / 2 STORY
5/28/2013 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
021. W/12" DIA. PIERS W/(3) #5 REBAR.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2ND FLOOR: 4BR, 4BA, PLAYROOM, LAUNDRY, PRAYER, OFFICE, BALCONY-X2, ELEVATOR
TEXAS DEPARTMENT OF LICENSING AND REGULATION
P.O. Box 12157 - Austin, Texas 78711-2157
1-800-803-9202 - (512) 463-6599 - FAX (512) 475-2871
www.license.state.tx.us - customer.service@license.state.tx.us
APPLICATION FOR: ELEVATOR INSTALLATION PER TDLR
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
THE HILLS OF KINGSWOOD PH 1
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | BHAMBRI, DR SANJAY & AVANI | ()- | | | FRISCO, TX 75034 |
MAIL TO | BHAMBRI, DR SANJAY & AVANI | ()- | | | FRISCO, TX 75034 |
APPLICANT | GREAT BAY RESIDENTIAL CONSTRUC | (214)502-7774 | sleonhart.greatbay@gmail.com | | PLANO, TX 75025 |
CONTRACTOR | GREAT BAY RESIDENTIAL CONSTRUC | (214)502-7774 | sleonhart.greatbay@gmail.com | | PLANO, TX 75025 |
ELECT. CTR. | BROTHERS ELECTRICAL SERVICES | (903)482-9351 | brothers.electrical2@yahoo.com | P.O. BOX 1844 | VAN ALSTYNE, TX 75454 |
FIRE CONT 2 | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
HERS PROVIDE | EIC COMFORT HOME INC | (972)485-4722 | PSMITH@COMFORTHOME.COM | 102 N. SHILOH ROAD #310 | GARLAND, TX 75042 |
MECH. CTR. | ENVIRONMENTAL CONTROLS | (972)219-9982 | PH23T@AOL.COM | PO BOX 292204 | LEWISVILLE, TX 75029 |
PLUM. CONT. | DEGREE PLUMBING AND CONSTRUCTI | (214)534-4523 | trags@sbcglobal.net | PO BOX 524 | MCKINNEY, TX 75070 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/19/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
7/18/2014
|
BACK FLOW FORM REVIEW |
$25.00
|
3/30/2018
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|