Permit Info
Short Description:
1 BF -FIRE PROT - 6300 AC, 8121 SQ FT, SFR \ 2 STORY
Expiration Date:
5/22/2019
Notes:
1 BF -FIRE PROT - 6300 AC, 8121 SQ FT, SFR \ 2 STORY
5/18/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BATTIER-FREE RAMP.
(5/18/2004 15:16 VI)SEE ENCLOSED BALCONY RAILING INFORMATION FROM IRC R-316
Parcel Info
City/State/Zip:
FRISCO, TX, 75034-6918
Subdivision:
STONEBRIAR COUNTRY CLUB ESTATES
|
BF TESTER | SCOTT MASDON | (214)587-4616 | probackflow@icloud.com | 5068 AVERY LN | THE COLONY, TX 75056 |
OWNER | AHMED, WASEEF & ROSALIA | ()- | | | FRISCO, TX 75034 |
MAIL TO | AHMED, WASEEF & ROSALIA | ()- | | | FRISCO, TX 75034 |
APPLICANT | PENHOLLOW CUSTOM HOMES | (972)907-1266 | | P O BOX 850394 | RICHARDSON, TX 75085 |
CONTRACTOR | PENHOLLOW CUSTOM HOMES | (972)907-1266 | | P O BOX 850394 | RICHARDSON, TX 75085 |
ELECT. CTR. | POTTER ELECTRIC X-01 | (972)442-1600 | | 10077 RETTOP RD | NEVADA, TX 75173 |
GEN. CONTR. | PENHOLLOW CUSTOM HOMES | (972)907-1266 | | P O BOX 850394 | RICHARDSON, TX 75085 |
IRRIGATION | LAKESIDE IRRIGATION X- 3/05 | (972)722-8020 | | 504 WILLOW SPRINGS DR. | ROCKWALL, TX 75032 |
MECH. CTR. | ROWLETT AIR | (972)475-1032 | | P.O. BOX 1305 | ROWLETT, TX 75088 |
PLUM. CONT. | THE PLUMBING CONNECTION | ()- | | 1546 HILTON HEAD LANE | FRISCO, TX |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/23/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
5/30/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
9/4/2015
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/24/2018
| | 5/30/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/22/2017
| | 5/22/2017 | |
More Info
|
BACKFLOW | APPROVED |
8/31/2015
| | 8/31/2015 | |
More Info
|
There are currently no reviews on this record.