Permit Info
Short Description:
1 BF FIRE PROT; 6171 AC, 7764 SF, SFR / 2 STORY
Approved Date:
10/10/2017
Expiration Date:
8/2/2018
Notes:
1 BF FIRE PROT; 6171 AC, 7764 SF, SFR / 2 STORY
3/10/2006 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
05. BEAMS=8"W X 26"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
TWO #4'S IN THE BOTTOM OF ALL BEAMS WITHOUT BEAM STRANDS.
2ND FLOOR WITH 3 BEDROOMS, 3 BATHS AND GAME ROOM.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
VILLAGES OF STONEBRIAR PARK #2 (CFR)
|
BF TESTER | DANNY R SMITHERMAN | (972)647-8172 | | 1171 RUGGLES DR | GRANDPRAIRIE, TX 75050 |
OWNER | CARR FAMILY LIVING TRUST | ()- | | EUGENE MITCHELL CARR & PATRICI | FRISCO, TX 75034-1863 |
MAIL TO | CARR FAMILY LIVING TRUST | ()- | | EUGENE MITCHELL CARR & PATRICI | FRISCO, TX 75034-1863 |
APPLICANT | BOB BOBBITT CO, INC. | (972)248-0800 | | 17110 DALLAS PKWY #230 | DALLAS, TX 75248 |
CONTRACTOR | BOB BOBBITT CO, INC. | (972)248-0800 | | 17110 DALLAS PKWY #230 | DALLAS, TX 75248 |
ELECT. CTR. | POTTER ELECTRIC X-01 | (972)442-1600 | | 10077 RETTOP RD | LAVON, TX 75166 |
GEN. CONTR. | BOB BOBBITT CO, INC. | (972)248-0800 | | 17110 DALLAS PKWY #230 | DALLAS, TX 75248 |
HERS PROVIDE | GUARANTEED WATT SAVER | (405)946-0206 | KELLYPAR@GWSSI.COM | 6444 NW EXPRESSWAY, SUITE 836A | OKLAHOMA CITY, OK 73132 |
IRRIGATION | TEXAS WATERBOYS, INC - X 9/07 | (972)733-4343 | | P.O. BOX 797068 | DALLAS, TX 75379 |
MECH. CTR. | CHAPMAN AIR & HEAT X-04/20 | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | DALLAS PLUMBING CO. X-09 | (214)340-6300 | | P.O. BOX 551648 | DALLAS, TX 75355 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/11/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/10/2017
| | 10/10/2017 | |
More Info
|
BACKFLOW | APPROVED |
8/2/2016
| | 8/2/2016 | |
More Info
|
There are currently no reviews on this record.