2 BF's FIRE PROT & steamer,9404 AC, 11713 SF, SFR / 2 STORY
4/10/2014 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 26"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
036. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
037. STAIR VERTICAL RISE OF 12' OR GREATER REQUIRES AN INTERMEDIATE LANDING
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
047. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 4BR, 4BA, GAME X2, PLAYROOM, UPPER DINNING, WASHER/DRY STACK, BALCONY
BUILDER MUST PROVIDE HVAC MANUAL " J " AND MANUAL " D " CALULATIONS TO THE CITY OF FRISCO PRIOR TO 2NDS INSPECTION.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE #17 (CFR)
|
BF TESTER | RICHARD FISK | (214)315-7290 | | 2044 STAGECOACH TRAIL | HEARTLAND, TX 75126 |
OWNER | KHANDAVALLI KISHORE & | ()- | | LAKSHMI BATLANKI | FRISCO, TX 75034-4090 |
MAIL TO | KHANDAVALLI KISHORE & | ()- | | LAKSHMI BATLANKI | FRISCO, TX 75034-4090 |
APPLICANT | VCH CONSTRUCTION LP | (972)335-5233 | dc@VENTURACUSTOMHOMES.COM | SUITE 113 | DALLAS, TX 75252 |
CONTRACTOR | VCH CONSTRUCTION LP | (972)335-5233 | dc@VENTURACUSTOMHOMES.COM | SUITE 113 | DALLAS, TX 75252 |
ELECT. CTR. | ROMAN ELECTRIC | (469)995-0634 | ROMAN.ELECTRIC@YAHOO.COM | | GRAND PRAIRIE, TX 75052 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | RIDDELL PLUMBING INC | (972)682-4860 | SCOTT@RIDDELLPLUMBING.COM | | MESQUITE, TX 75149 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$50.00
|
12/21/2016
|
BACK FLOW FORM REVIEW |
$50.00
|
1/2/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
12/18/2015
|
BACK FLOW FORM REVIEW |
$25.00
|
12/21/2015
|
Total Fees |
Charged: $150.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/13/2017
| | 12/13/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/13/2017
| | 12/13/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/8/2016
| | 12/8/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/8/2016
| | 12/8/2016 | |
More Info
|
BACKFLOW | APPROVED |
1/7/2016
| | 1/7/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/14/2015
| | 12/14/2015 | |
More Info
|
BACKFLOW | APPROVED |
12/2/2015
| | 12/2/2015 | |
More Info
|