Permit Info
Short Description:
1 BF -WATER SOFTENER 3499 AC, 4033 SF, SFR / 1 STORY
Approved Date:
12/14/2017
Expiration Date:
12/15/2018
Notes:
1 BF -WATER SOFTENER 3499 AC, 4033 SF, SFR / 1 STORY
4/20/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PHILLIPS CREEK RANCH PHASE 4B
|
BF TESTER | DON MCCLENDON | (972)632-7979 | BACKFLOWTESTER@OUTLOOK.COM | 2941 DOG LEG TRL | MCKINNEY, TX 75069 |
OWNER | AKHUD, RAVINDRA S & MINAL R | ()- | | | FRISCO, TX 75034 |
MAIL TO | AKHUD, RAVINDRA S & MINAL R | ()- | | | FRISCO, TX 75034 |
APPLICANT | AMERICAN LEGEND HOMES | (972)410-5701 | abaker@alhltd.com | | LEWISVILLE, TX 75056 |
CONTRACTOR | AMERICAN LEGEND HOMES | (972)410-5701 | abaker@alhltd.com | | LEWISVILLE, TX 75056 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
STRUCT ENG | ERIC L DAVIS ENGINEERING | (972)564-0592 | robp@eldengineering.com | | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/18/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
12/15/2016
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/14/2017
| | 12/14/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/15/2016
| | 12/15/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/31/2015
| | 12/31/2015 | |
More Info
|
There are currently no reviews on this record.