Permit Info
Short Description:
1 BF WATER/SOFT. 4295 AC, 5224 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
1/5/2018
Notes:
1 BF WATER/SOFT. 4295 AC, 5224 SF, SFR / 2 STORY
3/22/2013 12:00:00 AM
(3/22/2013 1:30 PM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(3/22/2013 1:30 PM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #1A (CFR)
|
BF TESTER | DON MCCLENDON | (972)632-7979 | BACKFLOWTESTER@OUTLOOK.COM | 2941 DOG LEG TRL | MCKINNEY, TX 75069 |
OWNER | PANDUGU GANDAIAB & | ()- | | VANDANA PANDUGU | FRISCO, TX 75035-0404 |
MAIL TO | PANDUGU GANDAIAB & | ()- | | VANDANA PANDUGU | FRISCO, TX 75035-0404 |
APPLICANT | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
7/18/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
7/14/2017
| | 7/14/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/5/2016
| | 1/5/2016 | |
More Info
|
There are currently no reviews on this record.