Permit Info
Short Description:
1 BF WATER SOFTENER 3506 AC, 4021 SF, SFR / 2 STORY
Expiration Date:
1/10/2019
Notes:
1 BF WATER SOFTENER 3506 AC, 4021 SF, SFR / 2 STORY
9/28/2009 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: 2- BED ROOMS, 1-BATH, GAME AND MEDIA ROOM.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
VILLAGE LAKES PH 1
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | TAYAL, AKHIL & JYOTSNA AGARWAL | ()- | | | FRISCO, TX 75034 |
MAIL TO | TAYAL, AKHIL & JYOTSNA AGARWAL | ()- | | | FRISCO, TX 75034 |
APPLICANT | MERITAGE HOMES | (972)580-6300 | MELISSA.GAJEWSKI@MERITAGEHOMES.COM | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
CONTRACTOR | MERITAGE HOMES | (972)580-6300 | MELISSA.GAJEWSKI@MERITAGEHOMES.COM | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | 225 GILBERT CIRCLE | GRAND PRAIRIE, TX 75050 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | AIRTRON INC. | (972)272-9633 | cherri.gains@resservices.com | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | MTEEMS@LSPLUMB.COM | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/30/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
2/22/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
There are currently no reviews on this record.