Permit Info
Short Description:
1 FIRE BF 5037 AC, 6405 SF, SFR / 2 STORY
Approved Date:
11/17/2017
Expiration Date:
11/21/2018
Notes:
1 FIRE BF 5037 AC, 6405 SF, SFR / 2 STORY
4/8/2016 12:00:00 AM
GARAGE ENCROACHMENT /SLC
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 3BR, 2BA, GAME, MEDIA, LARGE HALL, COVERED BALCONY RESOURCE CENTER.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
LATERA PHASE THREE (CFR)
|
BF TESTER | PARKER EAKINS | (214)701-1057 | backflow@gsfireprotectionllc.com | 1260 STACY RD | FAIRVIEW, TX 75069 |
OWNER | KHAN ZARTASH ZAFAR & MUHAMMAD NAEEM | ()- | | | FRISCO, TX 75035-2400 |
MAIL TO | KHAN ZARTASH ZAFAR & MUHAMMAD NAEEM | ()- | | | FRISCO, TX 75035-2400 |
APPLICANT | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 2557 SW GRAPEVINE PARKWAY #100 | Frisco, TX 75034 |
CONTRACTOR | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 2557 SW GRAPEVINE PARKWAY #100 | Frisco, TX 75034 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)701-1057 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NE | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)616-1100 | ahinson@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | POBRIANT@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | | RICHARDSON, TX 75081 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/30/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
11/27/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/17/2017
| | 11/17/2017 | |
More Info
|
BACKFLOW | APPROVED |
11/21/2016
| | 11/21/2016 | |
More Info
|
There are currently no reviews on this record.