Permit Info
Short Description:
1 FIRE PROT * SEPTIC * 8563 AC, 13405 SF, SFLWR / 1 STORY
Approved Date:
11/17/2017
Expiration Date:
11/17/2018
Notes:
1 FIRE PROT * SEPTIC * 8563 AC, 13405 SF, SFLWR / 1 STORY
2/26/2015 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONEBRIAR CREEK
|
BF TESTER | THOMAS STEHLIK | (214)350-1755 | TJSTEHLIK@HOTMAIL.COM | PO BOX 630886 | IRVING, TX 75063 |
OWNER | PAM BANKS | ()- | | PAMELA E BANKS TRUSTEE | FRISCO, TX 75034-6938 |
MAIL TO | PAM BANKS | ()- | | PAMELA E BANKS TRUSTEE | FRISCO, TX 75034-6938 |
APPLICANT | COOPER CONTRACTORS INC | (972)386-8894 | simmie@cooper-companies.com | 2201 MIDWAY ROAD #212 | CARROLLTON, TX 75006 |
CONTRACTOR | COOPER CONTRACTORS INC | (972)386-8894 | simmie@cooper-companies.com | 2201 MIDWAY ROAD #212 | CARROLLTON, TX 75006 |
ELECT. CTR. | B & E ELECTRIC | (214)905-0574 | benjaminr1@prodigy.net | | DALLAS, TX 75224 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | ADVANCED ENERGY SOLUTIONS | (972)423-2500 | energyrater@live.com | | ROWLETT, TX 75088 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | CIRCLE H PLUMBING | (214)587-3079 | circlehplumbing@sbcglobal.net | | ARLINGTON, TX 76003 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/27/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
11/17/2016
|
CREDIT CARD FEE |
$0.50
|
11/17/2016
|
Total Fees |
Charged: $50.50
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/21/2017
| | 11/21/2017 | |
More Info
|
BACKFLOW | APPROVED |
11/17/2016
| | 11/17/2016 | |
More Info
|
There are currently no reviews on this record.