Permit Info
Short Description:
1 BF FIRE PROT-5102 AC, 6206 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
3/18/2017
Notes:
1 BF FIRE PROT-5102 AC, 6206 SF, SFR / 2 STORY
9/30/2014 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
008. BEAMS=8"W X 28"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
027. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
028. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
047. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(9/30/2014 9:43 AM JC)
(FWF)
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS #8 (CFR)
|
OWNER | NAMBURI KRISHNA & SARADA | ()- | | | FRISCO, TX 75035-0533 |
MAIL TO | NAMBURI KRISHNA & SARADA | ()- | | | FRISCO, TX 75035-0533 |
APPLICANT | BOB BOBBITT CO INC | (214)618-9711 | BOB@BOBBITTHOMES.COM | | FRISCO, TX 75034 |
CONTRACTOR | BOB BOBBITT CO INC | (214)618-9711 | BOB@BOBBITTHOMES.COM | | FRISCO, TX 75034 |
ELECT. CTR. | OSCAR GONZALEZ CONSTRUCTION EL | (214)325-4423 | | | FARMERSVILLE, TX 754 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | energy@metrocode.com | | FT WORTH, TX 76102 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | aseutter@chapmanair.com | | DALLAS, TX 75238 |
PLUM. CONT. | RIDDELL PLUMBING INC | (972)682-4860 | SCOTT@RIDDELLPLUMBING.COM | | MESQUITE, TX 75149 |
STRUCT ENG | LR ENGINEERING | (972)964-2161 | | | PLANO, TX 75075 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.