Permit Info
Short Description:
NO BF FIRE PROT-4835 AC, 6218 SF, SFR / 2 STORY
Notes:
NO BF FIRE PROT-4835 AC, 6218 SF, SFR / 2 STORY
8/2/2011 12:00:00 AM
(8/2/2011 10:55 AM JC)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
018. BEAMS=12"W X 30"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(8/2/2011 11:03 AM JC)
2nd. story w/ (1) bedroom, (1) bath, game room & 10' x 10' exercise room.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 6A
|
OWNER | TURCHI, GLENN & CECILIA | ()- | | | FRISCO, TX 75033 |
MAIL TO | TURCHI, GLENN & CECILIA | ()- | | | FRISCO, TX 75033 |
APPLICANT | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
CONTRACTOR | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | BECKY.COLLIER@IES-CO.COM | 713 TOWER LANE SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | TEX ENERGY SOLUTIONS | (972)579-2009 | mendozam@texenergy.org | 2611 E PIONEER DR | IRVING, TX 75061 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | dripley@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | RANGER PLUMBING LLC | (214)585-6632 | D2HILT@HOTMAIL.COM | 5209 BOBTOWN ROAD | GARLAND, TX 75043 |
STRUCT ENG | NORTEX FOUNDATION DESIGNS | (817)379-0866 | info@nortexfoundation.com | 4416 KELLER HICKS RD | FORT WORTH, TX 76244 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.