Permit Info
Short Description:
1 BF - fire 5493 AC, 6550 SF, SFR / 2 STORY
Status:
RES LETTER TWO SENT
Expiration Date:
4/29/2018
Notes:
1 BF - fire 5493 AC, 6550 SF, SFR / 2 STORY
10/15/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
014. BEAMS=10"W X 28"D.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
033. ALL SIDING,TRIM,SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
046. SECOND STORY WINDOWS (SIZE & TYPE) MUST INCLUDE HEAD HEIGHT
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
15/25*GARAGE
2ND FLOOR: 3BD, 3B, MEDIA, GAME
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
LATERA PHASE THREE (CFR)
|
BF TESTER | JEFFERY SANDS | (817)222-1283 | JSANDS@IDEALPARNERSTX.COM | 6913 CAMP BOWIE BLVD | FORT WORTH, TX 76116 |
OWNER | MOOSA YUNUS & YASMIN | ()- | | | FRISCO, TX 75035-2403 |
MAIL TO | MOOSA YUNUS & YASMIN | ()- | | | FRISCO, TX 75035-2403 |
APPLICANT | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 9178 VITA DOLCE | Frisco, TX 75034 |
CONTRACTOR | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 9178 VITA DOLCE | Frisco, TX 75034 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)235-9395 | JMCDONALD@ENERGYINSPECTOR.COM | | PLANO, TX 75071 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)616-1100 | ahinson@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | POBRIANT@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | | RICHARDSON, TX 75081 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/8/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
5/10/2016
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/23/2017
| | 5/23/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/29/2016
| | 4/29/2016 | |
More Info
|
There are currently no reviews on this record.