Permit Info
Short Description:
1 BF - 4944 AC, 6270 SF, SFR / 2 STORY
Status:
RES LETTER ONE SENT
Expiration Date:
5/27/2018
Notes:
1 BF - 4944 AC, 6270 SF, SFR / 2 STORY
5/12/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
013. BEAMS=10"W X 26"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(11/2/2015 9:26 AM CLF)
THE FRONT YARD AREA BETWEEN THE BUILDING AND PROPERTY LINE MAY NOT EXCEED 50% IMPERMEABLE SURFACE AREA.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS #20 (CFR)
|
BF TESTER | JOSEPH WOLFE | (972)417-3592 | | 3017 KONET STREET | IRVING, TX 75060 |
OWNER | RAVI SAI K & DEEPTHI BOBBALA | ()- | | | FRISCO, TX 75035-0796 |
MAIL TO | RAVI SAI K & DEEPTHI BOBBALA | ()- | | | FRISCO, TX 75035-0796 |
APPLICANT | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 9178 VITA DOLCE | Frisco, TX 75034 |
CONTRACTOR | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 9178 VITA DOLCE | Frisco, TX 75034 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)235-9395 | JMCDONALD@ENERGYINSPECTOR.COM | | PLANO, TX 75071 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)616-1100 | ahinson@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | POBRIANT@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | | DALLAS, TX 75201 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/18/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/12/2018
| | 1/12/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/27/2016
| | 5/27/2016 | |
More Info
|
There are currently no reviews on this record.