Permit Info
Short Description:
6200 AC, 8136 SF, SFR / 2 STORY
Notes:
6200 AC, 8136 SF, SFR / 2 STORY
3/2/2006 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
09. BEAMS=10"W X 26"D.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2nd level: 2 bdrm. 2 ba. game & media, unfinished attic with no a/c
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | MILLER CHRIS & | ()- | | KELLI MILLER | FRISCO, TX 75034-7285 |
MAIL TO | MILLER CHRIS & | ()- | | KELLI MILLER | FRISCO, TX 75034-7285 |
APPLICANT | HANGARTNER CUSTOM HOMES, INC | (214)663-3358 | | 6480 BLUFFVIEW DR | FRISCO, TX 75034 |
CONTRACTOR | HANGARTNER CUSTOM HOMES, INC | (214)663-3358 | | 6480 BLUFFVIEW DR | FRISCO, TX 75034 |
ELECT. CTR. | HAMILTON PLUMBING X-2/05 | (972)423-6361 | | 1901 COUNTRY CLUB | PLANO, TX 75074 |
GEN. CONTR. | HANGARTNER CUSTOM HOMES, INC | (214)663-3358 | | 6480 BLUFFVIEW DR | FRISCO, TX 75034 |
HERS PROVIDE | ENERGY SENSE X-02-06 | (214)341-0668 | jason.mcalister@mascocs.com | 11111 PLANO ROAD | DALLAS, TX 75238 |
IRRIGATION | TEXAS WATERBOYS, INC - X 9/07 | (972)733-4343 | | P.O. BOX 797068 | DALLAS, TX 75379 |
MECH. CTR. | ABC HEATING & AIR X-9/06 | (972)423-7380 | | P.O. BOX 260104 | PLANO, TX 75026 |
PLUM. CONT. | RIDDELL PLUMBING, INC. X 2/07 | (972)682-4860 | | 242 S HWY 352 | SUNNYVALE, TX 75182 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/13/2016
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/8/2016
| | 3/15/2018 | |
More Info
|
There are currently no reviews on this record.