Permit Info
Short Description:
1 BF FIRE-7008 AC, 9048 SF, SFR / 2 STORY
Expiration Date:
6/17/2018
Notes:
1 BF FIRE-7008 AC, 9048 SF, SFR / 2 STORY
8/25/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
041. TEMPERED GLASS REQ'D AT WINDOWS ADJACENT TO STAIRS
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
049. FUEL BURNING APPLIANCE INSTALLATION WITHIN AN AC AREA MUST BE CODE COMPLIANT.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(8/25/2015 6:29 AM JC)
Tella Firma Found. system - Grade Beams : 8" x 28", Piers 12" dia. w/ vertical rebar per plan sch'l.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
HILLS OF KINGSWOOD, PH 1
|
BF TESTER | PARKER EAKINS | (214)701-1057 | backflow@gsfireprotectionllc.com | 1260 STACY RD | FAIRVIEW, TX 75069 |
OWNER | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
MAIL TO | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
APPLICANT | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
CONTRACTOR | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)701-1057 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | | PLANO, TX 75075 |
MECH. CTR. | BELL MECHANICAL SERVICES | (225)752-8538 | mike@bellmechanical.com | | BATON ROUGE, LA 70879 |
PLUM. CONT. | RAGSDALE PLUMBING CO INC | (903)450-4959 | RAGSDALEPLUMBINGINC@YAHOO.COM | | GREENVILLE, TX 75404 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/2/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
6/28/2016
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
7/24/2017
| | 7/24/2017 | |
More Info
|
BACKFLOW | APPROVED |
6/17/2016
| | 6/17/2016 | |
More Info
|
There are currently no reviews on this record.