Permit Info
Short Description:
1 BF - FIRE 5707 AC, 6937 SF, SFR / 2 STORY
Expiration Date:
9/26/2018
Notes:
1 BF - FIRE 5707 AC, 6937 SF, SFR / 2 STORY
2/9/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
024. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
***2ND STORY - GR, RC, 3BR, & 2BA***
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
LATERA PHASE THREE (CFR)
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | SHARDA MOHIT & DEVANSHI SURI | ()- | | | FRISCO, TX 75035-2405 |
MAIL TO | SHARDA MOHIT & DEVANSHI SURI | ()- | | | FRISCO, TX 75035-2405 |
APPLICANT | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 2557 SW GRAPEVINE PARKWAY #100 | Frisco, TX 75034 |
CONTRACTOR | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 2557 SW GRAPEVINE PARKWAY #100 | Frisco, TX 75034 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)701-1057 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)235-9395 | JMCDONALD@ENERGYINSPECTOR.COM | | PLANO, TX 75071 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)616-1100 | ahinson@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | POBRIANT@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | | RICHARDSON, TX 75081 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/5/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
1/30/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/24/2018
| | 1/24/2018 | |
More Info
|
BACKFLOW | APPROVED |
9/26/2016
| | 9/26/2016 | |
More Info
|