Permit Info
Short Description:
1 WATER SOFT 3982 AC, 4870 SF, SFR / 2 STORY
Approved Date:
10/20/2017
Expiration Date:
10/4/2018
Notes:
1 WATER SOFT 3982 AC, 4870 SF, SFR / 2 STORY
4/22/2006 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
07. BEAMS=8"W X 30"D.
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
42. PROVIDE SOIL MOISTURE TREATMENT DOCUMENTATION PRIOR TO STARTING CONSTRUCTION.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(4/22/2006 10:09 JC)
(2) 9'-0" x 18'-0" parking stalls req'd. within the (3) car garage, (1) shown.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
CYPRESS CREEK PHASE 1 (CFR)
|
BF TESTER | DON MCCLENDON | (972)632-7979 | BACKFLOWTESTER@OUTLOOK.COM | 2941 DOG LEG TRL | MCKINNEY, TX 75069 |
OWNER | PARISHE VIKRAM & | ()- | | SABBINENI SRAVANTHI | FRISCO, TX 75035-7394 |
MAIL TO | PARISHE VIKRAM & | ()- | | SABBINENI SRAVANTHI | FRISCO, TX 75035-7394 |
APPLICANT | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #200 | IRVING, TX 75038 |
CONTRACTOR | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #200 | IRVING, TX 75038 |
ELECT. CTR. | FOX ELECTRIC X-1/07 | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | DREES CUSTOM HOMES X-05/03 | (972)953-4500 | | 6051 STATE HIGHWAY #200 | IRVING, TX 75038 |
HERS PROVIDE | EIC, INC./COMFORT HOME X-03/2 | (972)485-4722 | CSIMPSON@COMFORTHOME.COM | 102 N. SHILOH ROAD #310 | GARLAND, TX 75042 |
IRRIGATION | DFW SITE DESIGN | ()- | | | |
MECH. CTR. | FRYMIRE ENGINEERING X-4/2006 | (972)620-3500 | | 2818 SATSUMA | DALLAS, TX 75226 |
PLUM. CONT. | LASITER & LASITER PLUMBING X- | (817)831-4245 | | P.O. BOX 14638 | HALTOM CITY, TX 76117 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING - X | (972)620-8204 | tami@strandsystems.com | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/26/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/20/2017
| | 10/20/2017 | |
More Info
|
BACKFLOW | APPROVED |
10/4/2016
| | 10/4/2016 | |
More Info
|
There are currently no reviews on this record.