Permit Info
Short Description:
1 BF - WATER SOFT3376 AC, 3981 SF, SNEW/ 2 STORY
Approved Date:
12/18/2017
Expiration Date:
11/11/2018
Notes:
1 BF - WATER SOFT3376 AC, 3981 SF, SNEW/ 2 STORY
4/18/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
016. BEAMS=10"W X 30"D.
025. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 3 RISERS OR MORE REQUIRE A HANDRAIL
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PRAIRIE VIEW #1 (CFR)
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | AVALA VENKATA REDDY & PRASANNA K CHEPPAL | ()- | | | FRISCO, TX 75035-8102 |
MAIL TO | AVALA VENKATA REDDY & PRASANNA K CHEPPAL | ()- | | | FRISCO, TX 75035-8102 |
APPLICANT | AMERICAN LEGEND HOMES | (972)410-5701 | lmoton@alhltd.com | | LEWISVILLE, TX 75056 |
CONTRACTOR | AMERICAN LEGEND HOMES | (972)410-5701 | lmoton@alhltd.com | | LEWISVILLE, TX 75056 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES | (972)292-1478 | MATTGOLDBERG@IN-CHARGE.ELECTRIC.COM | | LEWISVILLE, TX T5057 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NE | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | PREMIER PLUMBERS OF TEXAS | (972)542-5100 | SCHEDULE@PREMIERPLUMBERSOFTEXAS.COM | | MCKINNEY, TX 75069 |
STRUCT ENG | ERIC L DAVIS ENGINEERING INC | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/19/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/18/2017
| | 12/18/2017 | |
More Info
|
BACKFLOW | APPROVED |
11/11/2016
| | 11/11/2016 | |
More Info
|
There are currently no reviews on this record.