Permit Info
Short Description:
1 BF WATER SOFT 4090 AC, 5125 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
2/8/2018
Notes:
1 BF WATER SOFT 4090 AC, 5125 SF, SFR / 2 STORY
1/10/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 28"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
032. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
045. SECOND STORY WINDOWS (SIZE & TYPE) MUST INCLUDE HEAD HEIGHT
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 4BR, 4BA, GAME, MEDIA
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
MAINVUE AT PHILLIPS CREEK RANCH PHASE ONE
|
BF TESTER | AUSTIN ELIFF | (832)434-9661 | aeliff@dupure.com | 14555 PHILIPPHEST | HOUSTON, TX 44040 |
OWNER | GANARAJU, VAMSI & GADEY, NAGA | ()- | | | FRISCO, TX 75034-3982 |
MAIL TO | GANARAJU, VAMSI & GADEY, NAGA | ()- | | | FRISCO, TX 75034-3982 |
APPLICANT | HENLEY USA | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
CONTRACTOR | HENLEY USA | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)441-9795 | JMCDONALD@ENERGYINSPECTOR.COM | | MCKINNEY, TX 75071 |
MECH. CTR. | STARN AIR INC | (214)221-1313 | STARNAIRINC@AOL.COM | | GARLAND, TX 75042 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | JSANCHEZ@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | | | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.