Permit Info
Short Description:
4505 AC, 5477 SF, SFR / 2 STORY
Expiration Date:
5/31/2018
Notes:
4505 AC, 5477 SF, SFR / 2 STORY
9/29/2016 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
** BEAMS TYPE 1 = 10"W X 36"D
TYPE 2 = 10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
**** 2ND STORY - GR, M, 3BR, & 4BA ****
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
MAINVUE AT PHILLIPS CREEK RANCH PHASE TWO
|
BF TESTER | STANLEY WILSON | (214)695-0115 | | PO BOX 118114 | CARROLLTON, TX 75011 |
OWNER | MAINVUE TX LLC | ()- | | CAIRNCROSS & HEMPELMANN P.S. | BELLEVUE, WA 98004-4571 |
MAIL TO | MAINVUE TX LLC | ()- | | CAIRNCROSS & HEMPELMANN P.S. | BELLEVUE, WA 98004-4571 |
APPLICANT | MAINVUE TX LLC | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
CONTRACTOR | MAINVUE TX LLC | (972)754-0196 | jimmy.johnston@mainvuehomes.com | | PLANO, TX 75024 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
ENGINEER | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | CDMARQUARDT@MLAWDFW.COM | | AUSTIN, TX 78758 |
HERS PROVIDE | SYSTEMHAUSE LLC | (972)504-6800 | stan@systemhause.com | | PLANO, TX 75025 |
MECH. CTR. | TEMPO MECHANICAL SERVICES (mech) | (972)579-2000 | danny.buchanan@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | POBRIANT@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | CDMARQUARDT@MLAWDFW.COM | | AUSTIN, TX 78758 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/31/2017
| | 5/31/2017 | |
More Info
|
There are currently no reviews on this record.