Notes:
F08-0110 #3 POST N' PADDOCK
FENCE PLAN REVIEW NOTES
RETAINING WALL:
* ALL RETAINING WALLS MUST BE ON OR INSIDE THE PROPERTY LINE. RETAINING WALLS 36 INCHES OR GREATER IN HEIGHT MUST PROVIDE ENGINEERED PLANS. FENCE MAY NOT EXCEED 8 FEET FROM GRADE, MEASURED FROM INSIDE GRADE LEVEL.
* SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR PIER AND FOOTING INSPECTIONS PRIOR TO PLACING CONCRETE.
ITEM 1 WILL FALL UNDER THE POOL ENCLOSURE REQ'MENTS.
1. IRC 2006 312.2 No 4" sphere allowed to pass thru wrought iron railing. Maintain 2" gap between bottom rail of wrought iron fence and grade.
2. There shall not be at any point along the retaining wall depth, height, or width a step to allow climbing. All stone set flush in mortar joints constructed to prevent climbing is req'd.
(3 INSPECTIONS RQ'D).
A. Retaining wall base must be inspected before stacking begins.
B. At three feet an additional inspection is req'd.
C. Last inspection will be for the complete retaining wall. (misc. final)
ENGINEERED RETAINING WALL 0 - 5' IN HEIGHT & IRON FENCE