Permit Info
Short Description:
RETAINING WALL
Expiration Date:
3/17/2013
Notes:
RETAINING WALL
9/18/2012 12:00:00 AM
ENGINEERING COMMENTS:
1. All section details should include the statement “no voids” when specifying mortared zones.
2. Minimum one (1) embedment on all walls regardless of height per the International Building Code (IBC)
3. Include definition of “compacted fill” in details for soil beneath the walls and behind the walls, such that it may be verified by observation in the field.
*****ENGINEERING SERVICES PERFORMS CONTINUOUS OBSERVATION OF RETAINING WALL CONSTRUCTION FOR ALL ENGINEERED WALLS. PLEASE CONTACT JEFF WITT 972.292.5451 WITH ENGINEERING SERVICES PRIOR TO CONSTRUCTION MOBILIZATION TO COORDINATE WITH CITY STAFF FOR TIMELY OBSERVATIONS.****
BUILDING INSPECTION:
6 FT IN HEIGHT RETAINING WALL LOCATIONS AS SPECIFIED ON SITE PLAN AND REFERENCE APPROVED PLANS.
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR FOOTING AND BUILDING FINAL INSPECTION REQUIRED.
SHALL NOT BE LOCATED WITH ANY DEDICATED EASEMENTS.
LETTER OF ENGINEER FINAL ACCEPTANCE REQUIRED FOR INSPECTION AND CONSTRUCTION CONFORMANCE WITH DESIGN DRAWINGS.
PROVIDE EROSION CONTROL THROUGHOUT CONSTRUCTION. PROVIDE SOIL STABILIZATION AT COMPLETION OF PROJECT.
***ENGINEERS DESIGN WILL NOT SUPPORT SURCHARGE LOADS OF BUILDINGS.
***GRADING CHANGE SHALL NOT OBSTRUCT DRAINAGE OF ADJACENT PROPERTIES.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
CENTRE AT PRESTON RIDGE #2 THE (CFR)
|
OWNER | WESTWOOD RESIDENTIAL BUILDERS | (972)292-7656 | Jeff.lindsey@WESTWOODRESIDENTIAL.COM | | FRISCO, TX 75093 |
APPLICANT | ERWS INC | (817)267-1626 | NCHAPPELL@ERWSYS.COM | | EULESS, TX 76040 |
CONTRACTOR | ERWS INC | (817)267-1626 | NCHAPPELL@ERWSYS.COM | | EULESS, TX 76040 |
|
FENCE FEE |
$20.00
|
9/18/2012
|
Total Fees |
Charged: $20.00
Balance Due: $0.00
|
There are currently no inspections on this record.
|
FENCE REVIEW | Phillip Climer | Approved | 8/27/2012 | 9/18/2012 | 9/10/2012 |
More Info
|