Notes:
3/15/2018 11:42:51 AM
MEANDERING LN, BLOCK D, LOTS 13-24,
MEANDERING LN, BLOCK E, LOTS 1-12,
RENNER LN, BLOCK C, LOTS 9-17,
LUCY LN, BLOCK A, LOTS 5-20,
PENTONVILLE LN, BLOCK A, LOTS 21-27,
PENTONVILLE LN, BLOCK F, LOTS 1-7 & 12,
PLEASANT POINT LN, BLOCK E, LOT 28 (HOA LOT)
4/9/2018 4:09:37 PM
*****A PERSON WHO INTENDS TO REMOVE OR OTHERWISE DISTURB SOIL OF ANY R.O.W. OR EASEMENT HELD BY THE CITY SHALL FIRST OBTAIN A PERMIT FROM THE PUBLIC WORKS R.O.W. MANAGER AND CITY UTILITY LINE LOCATES. 11300 RESEARCH ROAD (972)292-5800
A PERSON WHO INTENDS TO REMOVE OR OTHERWISE DISTURB SOIL TO A DEPTH OF 16 OR MORE INCHES SHALL NOTIFY A TEXAS ONE CALL NOTIFICATION CENTER NOT EARLIER THAN THE 14TH DAY BEFORE THE DATE THE EXCAVATION IS TO BEGIN OR LATER THAN THE 48TH HOUR BEFORE THE TIME THE EXCAVATION IS TO BEGIN IN ACCORDANCE WITH STATE LAW (DIAL 811)
*****BUILDING INSPECTIONS PERFORMS CONTINUOUS OBSERVATION OF ALL RETAINING WALL CONSTRUCTION. PLEASE CONTACT COLE STALLCUP 214.425.4810 VSTALLCUP@FRISCOTEXAS.GOV WITH BUILDING INSPECTIONS PRIOR TO CONSTRUCTION MOBILIZATION TO COORDINATE WITH CITY STAFF FOR TIMELY OBSERVATIONS.****
11.4 FT IN HEIGHT RETAINING WALL LOCATIONS AS SPECIFIED ON SITE PLAN AND REFERENCE APPROVED PLANS.
SHALL NOT BE LOCATED WITH ANY DEDICATED EASEMENTS.
LETTER OF ENGINEER FINAL ACCEPTANCE REQUIRED FOR INSPECTION AND CONSTRUCTION CONFORMANCE WITH DESIGN DRAWINGS.
PROVIDE EROSION CONTROL THROUGHOUT CONSTRUCTION. PROVIDE SOIL STABILIZATION AT COMPLETION OF PROJECT.
***FLOODWAY EASEMENT SHALL NOT BE DISTURBED OR RE-GRADED FROM EXISTING CONDITIONS.
***ENGINEERS DESIGN WILL NOT SUPPORT SURCHARGE LOADS OF BUILDINGS.
***NO PORTION OF RETAINING WALL SHALL BE LOCATED IN ADJACENT FLOODWAY EASEMENT.
***GRADING CHANGE SHALL NOT OBSTRUCT DRAINAGE OF ADJACENT PROPERTIES.
***FENCE REPLACEMENT NOT SHOWN. SEPARATE PERMIT REQUIRED.
***SUBDIVISION HOA APPROVED MAY BE REQUIRED.
*** ENGINEER OF RECORD CREATING PLAT SHALL PROVIDE SCREENING WALL MAINTENANCE EASEMENT FOR ALL SECTIONS NOT LOCATED WITHIN H.O.A SCREENING AND LANDSCAPE DESIGNATION.
***DRAINAGE SWALE SHALL BE LOCATED ON HIGH SIDE OF WALL WHEN WALL IS LOCATED WITHIN 1' OF PROPERTY LINE.
***GRADING SHALL COMPLY WITH ALL DETAILS OF CIVIL DESIGN DRAWINGS.
***DRAINAGE MATERIAL SHALL BE FREE OF FOREIGN DEBRIS.
***IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND CONTRACTOR TO COORDINATE WITH ADJACENT DEVELOPMENT AND HOMES TO AVOID PROPERTY DAMAGE AND ENCUMBRANCES UPON THEIR PRIVATE PROPERTY. IT IS HIGHLY RECOMMENDED TO NOTIFY RESIDENTS OF INTENTS PRIOR TO MOBILIZATION TO AVOID CONFLICT AND BE A GOOD NEIGHBOR AND DEVELOPER OF FRISCO. WHEN NUISANCE ARE CREATED BY INSTALLATION OF PARALLEL FENCES OR RETAINING WALLS, ACTION WILL BE TAKEN UPON ALL PROPERTIES DEEMED A CAUSE OF THE NUISANCE.