Permit Info
Short Description:
INSTALL HVAC
Expiration Date:
1/23/2006
Notes:
1- CONTINGENT UPON COMPLIANCE WITH BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- SHELL RECORDS SHOW EXISTING BACK DOOR OPENING NOT IN SAME PLACE WHERE THE PROPOSED BACK EXIT DOOR IS SHOWN ON PLAN. OPENING OF NEW DOORS THRU STRUCT'L TILT-UP CONC. PANELS ARE NOT PERMISSIBLE UNLESS STRUCT'L ENGR'S DETAILS ARE SUBMITTED DESCRIBING THE METHOD & THE EXACT LOCATION OF THE NEW CUT-OUT OPNGS WITHIN THE TILT-UP PANEL AREA. DTLS OF ANY NECESSARY STRUCT'L REINFORCING MUST BE INCLUDED (IF REINFORCING IS NOT NECESSARY, IT MUST BE CLEARLY NOTED BY THE ENGR).
3- ALTHOUGH GENERAL NOTES ON DWG 10 OF 12 CONTAIN SOME REFERENCES TO NITROUS OXIDE (NO2) & OXIGEN (O2), INSTALLATION OF MED. GASES FACILITY IS NOT IN CONTRACT, AS DECLARED ON THE FACILITY CHECKLIST SIGNED BY THE GEN. CONTRACTOR, AND, THEREFORE, NOT INCLUDED IN THIS PERMIT. ANY USE OF MED. GASES SHALL BE PROHIBITED UNLESS SPECIFIC SYSTEM PLANS (CONFORMING TO NFPA 99) ARE SUBMITTED FOR APPROVAL.
4- DOCTOR'S PETITION FOR ALTERNATIVE INSTALLATION OF AN ACCESSIBLE BACTERIA-FREE JUICES & WATER BAR, DESIGNED AS AN "EQUIVALENT FACILITY" TO A HI/LO (BI-LEVEL) DRINKING FOUNTAIN, IS ACCEPTABLE PROVIDED THAT PROPOSED DESIGN, LOCATION & DTLS ARE SUBMITTED AND APPROVED.
5- ELECTRICAL CLOSET'S WALLS TO BE 1 HR UL-U465 TO DECK (OR TO APPROVED 1 HR CLG) WITH 45 MINUTE DOOR IN 1 HR FRAME.
6- ALL WORKS TO BE OF NON-COMBUSTIBLE COSTRUCTION WITH METAL STUD PARTITIONS AT 16" O/C. & 5/8" GYP. BD. ANY WOOD USED FOR BLOCKING MUST BE FIRE-RES.-TREATED.
7- PROVIDE FURR-OUT FINISH AT EXTERIOR WALLS WITH R-11 INSULATION BETWEEN MTL STUDS (IF NOT ALREADY PROVIDED BY THE SHELL). NO FINISH TO EXCEED 200 FLAME SPREAD OR 450 SMOKE DEVELOPED (MUST SUBMIT MANUF. DOCUMENTATION). FIRE EXTINGUISHERS AS PER FIRE MARSHAL.
8- NEW STOREFRONT DOOR AND ADJACENT GLASS TO BE TEMPERED GLASS TO MATCH STOREFRONT'S SYSTEM.
9- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
INSTALL HVAC
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
LEGACY RANCH
|
OWNER | ESA CONSTRUCTION | (972)250-1170 | | 6825 LEVELAND | DALLAS, TX 75252 |
APPLICANT | ACTION HEATING & AIR X-6/05 | (972)442-4335 | | 110 N. FOURTH ST. | WYLIE, TX 75098 |
CONTRACTOR | ACTION HEATING & AIR X-6/05 | (972)442-4335 | | 110 N. FOURTH ST. | WYLIE, TX 75098 |
GEN. CONTR. | ACTION HEATING & AIR X-6/05 | (972)442-4335 | | 110 N. FOURTH ST. | WYLIE, TX 75098 |
MECH. CTR. | ACTION HEATING & AIR X-6/05 | (972)442-4335 | | 110 N. FOURTH ST. | WYLIE, TX 75098 |
|
MISCELLANOUS MECHANICAL FEES |
$57.50
|
7/27/2005
|
Total Fees |
Charged: $57.50
Balance Due: $0.00
|
|
MECHANICAL | APPROVED |
8/9/2005
| PM | 8/9/2005 | |
More Info
|
There are currently no reviews on this record.