Notes:
POOL ONLY - STONELAKES AMENITY CENTER
2/3/2006 12:00:00 AM
STONELAKES AMENITY CENTER
SPACING IN FENCE NOT EXCEED 4 INCHES. GATES TO SELF CLOSING/LATCHING AND BE LOCKABLE. RESTROOM LAVATORIES AND SHOWER MUST HAVE HOT WATER AND DRAIN TO SANITARY SEWER. EQUIPMENT ROOM MUST HAVE ADEQUATE VENTILATION - LOUVERED OR MECHANICAL - AND HAVE LOCKABLE ACCESS. ALL LEADING EDGES OF BENCHES, STEPS AND LEDGES REQUIRE 1 INCH MINIMUM TILE STRIPE. LIGHTS MUST BE PROTECTED BY GFCI. CHAIRLIFT SLEEVE SHALL BE WITHIN 24 INCHES OF WATER'S EDGE. SEE ATTACHED CHECKLIST FOR GUIDELINES ON SIGNAGE REQUIREMENTS. TWO SETS OF SAFETY EQUIPMENT ARE REQUIRED. AUTOFILL LINE, IF PROVIDED, MUST NOT PROTRUDE BEYOND COPING EDGE. KNOX BOX LOCATED OUTSIDE OF POOL BARRIER. PROVIDE AND LOCATE WATER FOUNTAINS. PROVIDE AND LOCATE EMERGENCY 911 PHONE. ENGINEER RECOMMENDS REMOVAL OF PLANTER. REST ROOMS REQUIRE BABY CHANGING STATIONS. "NO DIVING AND INTERNATIONAL SYMBOL MUST BE PROVIDED MINIMUM OF EVERY 25 FT. ENTRY/EXITS MUST BE PROVIDED EVERY 75 FT. OF POOL WALL LENGTH OR FRACTION OF.ADDITIONAL LADDER REQUIRED. POOL - 2581 SQ. FT. REQUIRES 5 SKIMMERS, 2 RETURN INLET FOR SUNLEDGE AND 9 RETURN INLETS FOR MAIN BODY OF POOL MINIMUM
BATHER LOAD: LG. POOL = 150 PERSONS.