Notes:
POOL / CYPRESS CREEK AMENITY CENTER
5/13/2006 12:00:00 AM
CYPRESS LAKES POOLS:
SHOWER AND LAVATORIES MUST HAVE HOT WATER AVAILABLE. SHOWER MUST BE LOCATED WITHIN THE POOL ENCLOSURE. BABY CHANGING TABLE REQUIRED IN RESTROOMS (ONE MEN/ONE WOMEN - MINIMUM). POOL BARRIER MUST MEET STATE MINIMUM STANDARDS.
NO GAPS IN FENCE > 4". GATES TO SELF CLOSING/LATCHING AND BE LOCKABLE. EQUIPMENT ROOM MUST HAVE ADEQUATE VENTILATION - LOUVERED OR MECHANICAL, AND HAVE LOCKABLE ACCESS. ALL LEADING EDGES OF BENCHES, STEPS AND LEDGES REQUIRE 1 INCH MINIMUM TILE STRIPE IN CONTRASTING COLOR. DEPTH MARKERS ALSO REQUIRED ON VERTICAL POOL WALL. PROVIDE DEPTH AND NO DIVING TILE MARKERS AND INTERNATIONAL SYMBOL A MINIMUM OF EVERY 25 FEET . LIGHTS MUST BE PROTECTED BY GFCI. CHAIRLIFT SLEEVE SHALL BE WITHIN 24 INCHES OF WATER'S EDGE AND BE PROVIDED WITH A COVER. SEE ATTACHED CHECKLIST FOR GUIDELINES ON SIGNAGE REQUIREMENTS. AUTOFILL LINE MUST NOT PROTRUDE BEYOND COPING EDGE. PROVIDE AND LOCATE KNOX BOX FOR POOL AREA ENCLOSURE. ½ MAX. INCH SCREEN MESH MUST BE INSTALLED AT LEAST 18 INCHES IN ALL DIRECTIONS FROM LATCHING MECHANISM ON EACH GATE. PROVIDE AND LOCATE EMERGENCY 911 PHONE. MINIMUM 4FT. OF DECK AROUND POOLS. KIDDIE POOL MUST BE MINIMUM 15 FT. FROM SHALLOW END OF BIG POOL. ENTRIES/EXITS MUST BE PROVIDED EVERY 75FT OF POOL WALL. KEEP LADDERS OUT OF SWIM LANE.