01. DUAL MAIN DRAINS REQUIRED ON EACH SUCTION LINE. MINIMUM 3' BETWEEN INSIDE EDGES OF EACH SET OF DRAIN COVERS. ALL SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION.
02. DIVING BOARDS AND SLIDES AND THEIR ASSOCIATED ENVELOPES MUST MEET NATIONAL STANDARDS (NSPI OR CPSC) AND BE INSTALLED PER MANUFACTURER INSTRUCTIONS.
03. GAS VENT TO TERMINATE MINIMUM 5' HORIZONTAL FROM OPENABLE WINDOW OR 3' MINIMUM ABOVE.
04. WINDOWS WITHIN 36" OF WALKER OR < 5' TO WATER MUST BE TEMPERED/SAFETY GLAZED TO CODE.
05. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
06. CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD.
07. PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT.
08. EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE < 6 HRS.
09. POOLS AND SPAS MUST BE DESIGNED & CONSTRUCTED IN ACCORDANCE WITH NSPI STANDARDS AND THE CURRENT IRC AS ADOPTED & AMENDED.
10. BACKWASH LINE MUST BE INSTALLED AT TIME OF TRAP INSPECTION TO INSURE PROPER AIR GAP.
11. CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES
12. PLEASE NOTE: THIS PLACARD DOES NOT INCLUDE ALL REQUIREMENTS.
13. NO ELECTRICAL CONDUCTORS SMALLER THAN NUMBER 12 COPPER ALLOWED.
14. POOL BEAM MUST BE BUILT ACCORDING TO PLANS NEAREST THE HOUSE FOUNDATION AT DEEPEST PART OF POOL OR ENGINEER'S LETTER REQUIRED. ON THE 11780 BLACKHAWK DRIVE ,FRISCO, TEXAS PROJECT WE HAVE A POOL BENCH (5' FROM HOUSE) AT 21" BELOW BEAM DEPTH THEN DROPPING TO 54 " AT THE FLOOR DEPTH (6'-6" FROM HOUSE) TO EXCEDE THE 1:1 RATIO.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
FAIRWAYS #06 THE
|
OWNER | BEAU BEAULIEU | (214)762-4990 | | 11780 BLACKHAWK DR | FRISCO, TX 75034 |
APPLICANT | CLAFFEY POOLS | (817)488-5795 | | 1625 BRUMLOW | SOUTHLAKE, TX 76092 |
ELECT. CTR. | MACKIE ELECTRIC X-12/08 | (817)759-2000 | | 3819 AUSTIN LANE | FT WORTH, TX 76111 |
POOL CONTRAC | CLAFFEY POOLS | (817)488-5795 | | 1625 BRUMLOW | SOUTHLAKE, TX 76092 |
PLUMBING | SOUTHWESTERN PLUMBING CO. - | (214)675-5424 | salexander@entact.com | 13391 GEORGE FOSTER | PONDER, TX 76259 |
|
SPA/ABOVE GROUND POOL PERMIT F |
$50.00
|
4/14/2008
|
POOL PLUMBING FEE |
$20.00
|
4/14/2008
|
POOL ELECTRIC FEE |
$10.00
|
4/14/2008
|
IN-GROUND POOL BUILDING PERMIT |
$100.00
|
4/14/2008
|
Total Fees |
Charged: $180.00
Balance Due: $0.00
|
There are currently no inspections on this record.
|
INITIAL REVIEW | Diana Torres-Biggers | | 3/28/2008 | | 4/18/2008 |
More Info
|
POOL REVIEW | Gregory P Kelsey | Appd w/ Conditions | 3/28/2008 | | 4/18/2008 |
More Info
|