Notes:
POOL AND SPA
6/13/2008 12:00:00 AM
01. DUAL MAIN DRAINS REQUIRED ON EACH SUCTION LINE. MINIMUM 3' BETWEEN INSIDE EDGES OF EACH SET OF DRAIN COVERS. ALL SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION.
02. DIVING BOARDS AND SLIDES AND THEIR ASSOCIATED ENVELOPES MUST MEET NATIONAL STANDARDS (NSPI OR CPSC) AND BE INSTALLED PER MANUFACTURER INSTRUCTIONS
03. GAS VENT TO TERMINATE MINIMUM 5' HORIZONTAL FROM OPENABLE WINDOW OR 3' MINIMUM ABOVE.
04. WINDOWS WITHIN 36" OF WALKER OR < 5' TO WATER MUST BE TEMPERED/SAFETY GLAZED TO CODE.
05. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
06. CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD.
07. PATIO COVERS, ARBO
*****Check permit P08-0379 and P08-0458 for prior inspection approvals of D-steel, B-steel and Gas Trap. PDC