Notes:
SPA ONLY
2/5/2010 12:00:00 AM
(2/5/2010 8:58 AM RET)
01. SPA MUST BE DESIGNED & CONSTRUCTED IN ACCORDANCE WITH ANSI/ NSPI STANDARDS AND THE CURRENT IRC AS ADOPTED & AMENDED.
02. GAS VENT TO TERMINATE MINIMUM 5' HORIZONTAL FROM OPENABLE WINDOW OR 3' MINIMUM ABOVE.
03. WINDOWS WITHIN 36" OF WALKWAY OR < 5' TO WATER MUST BE TEMPERED/SAFETY GLAZED TO CODE.
04. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
05. CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD.
06. PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT.
07. EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE < 6 HRS.
0.8 FENCE/ SPA BARRIER MUST ANSI/NSPI STANDARDS AND THE 2006 IRC AS ADOPTED & AMENDED.
0.9 ELECTRCIAL ISTALLATIONS MUST MEET ALL NEC 70 2005 ADDITON PER ARTICLE 680.40- 680.44