Notes:
165 SQ FT / OLD HICKORY SQUARE APT. NORTH FOUNTAIN
1/11/2012 12:00:00 AM
NORTH FOUNTAIN
W.01: IDENTIFY LOCATION OF CHLORINATOR AND FILTER. DUAL HYDRAULICALLY BALANCED MAIN DRAINS REQUIRED ON EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALL OR FEATURES. MAIN DRAIN COVERS/GRATES MUST BE ANSI/ASME A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED AND MUST HAVE MINIMUM 3 FT SEPARATION BETWEEN INSIDE EDGES OF COVER/GRATE TO COVER/GRATE. FOUNTAIN DEPTH MAY NOT EXCEED 18 INCHES. MAIN DRAIN PIPING MUST BE INSTALLED IN AN APPROVED METHOD FOR HYDRAULICLLY BALANCE. IF FIELD BUILT SUMPS AND/OR CUSTOM COVERS (GRANITE), SUBMIT PRE-AND POST- CONTRUCTION ENGINEER LETTERS. SIGNAGE MUST BE PERMANENTLY AFIXED TO FOUNTAIN STATING "FOUNTAIN ONLY - NO SWIMMING - NO DIVING." SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION. ENSURE NO ENTRAPMENT HAZARDS. CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
*** SEE PLAN REDLINE COMMENTS.
CALL FOR INSPECTION