Notes:
KIDS R KIDS SPLASH PAD
11/1/2013 12:00:00 AM
SPECIAL AQUATIC ACTIVITY DEVICE/SPRAY PARK MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH TAC. PART 1, SUBCHAPTER M, SECTION 265.300-265.308.
CIRCULATION SYSTEM MUST TURNOVER < OR = 30 MINUTES.
MUST HAVE POTABLE WATER FOR REFILL OF BALANCE TANK.
FILTRATION SYSTEM MUST BACKWASH TO SANITARY SEWER SYSTEM.
MUST HAVE AUTO DISINFECTION/CHEMICAL SYSTEM AND MAINTAIN STATE MINIMUM STANDARDS FOR WATER QUALITY.
MUST MEET APPLICABLE ELECTRIC & PLUMBING CODES.
MUST PROVIDE ALL SIGNS LISTED ON PERMIT PLAN SET INCLUDING NON-EMERGENCY CONTACT PHONE NUMBER MUST BE POSTED WHEN NO ONSITE OPERATOR/OWNER & 2 INCH “CLOSED” SIGN WHEN SPLASH PAD NOT IN USE.
EQUIPMENT ELECTRICAL DISCONNECT MUST BE VISIBLE INSIDE POOL EQUIPMENT ROOM.
APPROVED PERMIT SET OF PLANS TO BE ON JOBSITE AT ALL TIMES.
POOL BACKWASH MUST BE PLUMBED TO AIR GAP & P-TRAP AND DRAIN TO SANITARY SEWER LINE.
USE OF CARTRIDGE FILTERS ON COMMERCIAL POOLS & SPAS IS PROHIBITED. CARTRIDGE FILTER APPROVED FOR RECIRCULATION SYSTEM ON SPLASHPAD.
SPRAY PARK PAD SHALL BE CONTRUCTED & GRADED TO MINIMIZE STORM WATER TO DECK DRAINS CATCHING RUN OFF PIPED TO COLLECTOR TANK.
BALANCE TANK MUST HAVE OVERFLOW LEVEL TO PREVENT POSSIBILITY OF SUCTION AT DRAIN.
PROVIDE OBSERVABLE WASTE WATER DISCHARGE, SITE GLASS OR FREE FALL. RETURN WATER TO BE TREATED AND AUTOMATICALLY DISINFECTED, AND HAVE A MEANS OF SECONDARY DISINFECTED.
PERMANENTLY LABEL ALL EXPOSED PIPING AT EQUIPMENT. EQUIPMENT MUST HAVE LOCKABLE FENCE AROUND IT.
MUST PROVIDE TEST PORT ON RETURN SIDE OF AUTO DISINFECTANT EQUIPMENT IN ORDER TO SAMPLE WATER.
STORAGE ROOM VENTILATED IF USED TO STORE CHEMICALS.
SPRAY PARK (WATER & EQUIPMENT) MUST BE MAINTAINED BY A CERTIFIED POOL OPERATOR (CPO).
FACILITY MUST BE SUPERVISED WHEN IN USE AND MUST BE LOCKED WHEN NOT IN USE TO PREVENT UNAUTHORIZED ACCESS.