11/20/2017 4:34:57 PM
PROJECT MUST COMPLY WITH POOL ORDINANCE (REGARDING POOL ENCLOSURE AND GATE), TDSHS MINIMUM STANDARDS FOR POOLS AND SPAS, ADA RULES. THIS INCLUDES SITE DECK AND POOL LIGHTING, RESTROOMS, ON-DECK SHOWER AND EMERGENCY PHONE.
REVIEW DID NOT INCLUDE ‘NUTRITION BAR’. MUST SUBMIT FOOD SERVICE AREAS SEPARATELY IF THEY WERE NOT PART OF ORIGINAL SUBMITTAL.
**PROVIDE LETTER FROM OWNER/OPERATOR AT OR BEFORE FINAL INSPECTION STATING PLUNGE POOLS ARE UNDER THE DIRECT SUPERVISION AND CONTROL OF LICENSED MEDICAL PERSONNEL.
ENSURE OBSERVABLE WASTE WATER DISCHARGE OR REMOVABLE SITE GLASSES INSTALLED.
EMERGENCY SUMMONING DEVICE SHALL BE LOCATED WITHIN 100 FT. OF WATER’S EDGE.
PROVIDE EMERGENCY SHUT OFF WITHIN SIGHT OF EACH PLUNGE POOL OUTSIDE OF 5 FT. TO WATER’S EDGE; “(LOCATION OF EMERGENCY PHONE)” LETTERS MINIMUM ONE (1) INCH. REQUIRED INSIDE THE POOL BARRIER IF THE EMERGENCY PHONE IS NOT READILY VISIBLE FROM THE POOL AND SPA.
LABEL SWITCH/BUTTON AS “EMERGENCY SPA SHUT OFF”.
PROVIDE ELECTRICAL DISCONNECT WITHIN SIGHT OF EQUIPMENT.
POST “FOR EMERGENCY DIAL 911” OR APPROPRIATE PHONE OPERATING INSTRUCTIONS AT EMERGENCY PHONE. LETTERS MINIMUM ONE (1”) INCH HIGH. FOR EXAMPLE: “PUSH BUTTON TO DIAL 9-1-1”.
“(PHYSICAL ADDRESS OF POOL)” REQUIRED NEXT TO PHONE AND LEGIBLE.
“(LOCATION OF EMERGENCY PHONE AT ALL POOL BARRIER ENTRANCES)” LETTERS MINIMUM ONE (1) INCH. REQUIRED IF GATES ARE LOCKED.
MAXIMUM POOL LOAD LIMITS SHALL BE POSTED.
GENERAL PLUNGE RULES SHALL BE POSTED.
LIGHTING FOR DECKS AND WATER SURFACES SHALL BE SPACED TO PROVIDE ILLUMINATION TO ALL PORTIONS OF THE DECK AND WATER SURFACE AREAS; BE NOT LESS THAN 0.5 WATTS PER SQ. FT. OF COMBINED WATER/DECK SURFACE AREAS. IF UNDERWATER LIGHTING IS PROVIDED AND IS 0.5 WATT PER SQ. FT WATER SURFACE AREA, THIS AREA NEED NOT BE CALCULATED IN DECK LIGHTING REQUIREMENT.
HOT AND COLD WATER ARE REQUIRED AT PUBLIC LAVATORIES AND SHOWER; WATER SUPPLIED MUST BE TEMPERED VIA THERMOSTATIC MIXING VALVE TO MAXIMUM 110 DEGREES.