Notes:
12/1/2020 9:34:31 AM
P20-00542
PENDING: SUBMIT APPLICATION, CPO & FEES.
MUST PROVIDE POST ENGINEER LETTER.
(2) SAND FILTERS PROVIDED.
SPECIAL AQUATIC ACTIVITY DEVICE/SPRAY PARK MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH TAC. PART 1, SUBCHAPTER M, SECTION 265.300-265.308.
AMUSEMENT RIDES ARE DEFINED IN THE OCCUPATIONS CODE, 2151.002 (relating to the Amusement Ride Safety Inspection & Insurance Act) AND 28 TAC 5.9001-5.9014, Subchapter J. Sent link to Brett Holliday on November 30, 2020. MUST POST SLIDE APPROVED INSPECTION AT SLIDE BEFORE POOL FINAL CAN BE SCHEDULED.
MUST HAVE POTABLE WATER FOR REFILL OF BALANCE TANK.
FILTRATION SYSTEM MUST BACKWASH TO SANITARY SEWER SYSTEM.
MUST HAVE AUTO DISINFECTION/CHEMICAL SYSTEM AND MAINTAIN STATE MINIMUM STANDARDS FOR WATER QUALITY.
MUST MEET APPLICABLE ELECTRIC & PLUMBING CODES.
MUST PROVIDE ALL SIGNS LISTED ON PERMIT PLAN SET INCLUDING NON-EMERGENCY CONTACT. PHONE NUMBER MUST BE POSTED WHEN NO ONSITE OPERATOR/OWNER & 2 INCH “CLOSED” SIGN WHEN SPLASH PAD NOT IN USE.
SCHEDULE ELECTRICAL FINAL BEFORE POOL FINAL.
EQUIPMENT ELECTRICAL DISCONNECT MUST BE VISIBLE INSIDE SPLASHPAD EQUIPMENT ROOM.
APPROVED PERMIT SET OF PLANS TO BE ON JOBSITE AT ALL TIMES.
POOL BACKWASH MUST BE PLUMBED TO AIR GAP & P-TRAP AND DRAIN TO SANITARY SEWER LINE.
LABEL CIRCULATION PIPING WITH FUNCTION & FLOW DIRECTION. REFER BELOW FOR GAUGE/PIPING REQUIREMENTS.
SPRAY PARK PAD SHALL BE CONTRUCTED & GRADED TO MINIMIZE STORM WATER TO DECK DRAINS CATCHING RUN OFF PIPED TO COLLECTOR TANK.
BALANCE TANK MUST HAVE OVERFLOW LEVEL TO PREVENT POSSIBILITY OF SUCTION AT DRAIN.
PROVIDE OBSERVABLE WASTEWATER DISCHARGE, SITE GLASS OR FREE FALL. RETURN WATER TO BE TREATED AND AUTOMATICALLY DISINFECTED AND HAVE A MEANS OF SECONDARY DISINFECTED.
PERMANENTLY LABEL ALL EXPOSED PIPING AT EQUIPMENT. EQUIPMENT MUST HAVE LOCKABLE FENCE AROUND IT. ENSURE TREATMENT TANK IS CAPABLE OF COMPLETELY DRAINING.
MUST PROVIDE TEST PORT ON RETURN SIDE OF AUTO DISINFECTANT EQUIPMENT IN ORDER TO SAMPLE WATER.
STORAGE ROOM VENTILATED IF USED TO STORE CHEMICALS.
SPRAY PARK (WATER & EQUIPMENT) MUST BE MAINTAINED BY A CERTIFIED POOL OPERATOR (CPO).
FACILITY MUST BE SUPERVISED WHEN IN USE AND MUST BE LOCKED WHEN NOT IN USE TO PREVENT UNAUTHORIZED ACCESS.
SIGNS FOR PIWF
SIGNAGE REQUIRED (ALL 2-INCH LETTERS):
1. “NON-SERVICE ANIMALS PROHIBITED”;
2. “CHANGING DIAPERS WITHIN 6 FEET OF THE WATER FEATURE IS PROHIBITED”;
3. USE OF THE WATER FEATURE IF ILL WITH A CONTAGIOUS DISEASE OR DIARRHEA IS PROHIBITED”;
4. “DO NOT DRINK WATER FROM THE WATER FEATURE”;
5. A SIGN TO USE WHEN POOL IS VOLUNTARILY/INVOLUNTARILY CLOSED; AND,
6. NON-EMERGENCY CONTACT PHONE NUMBER MUST BE POSTED WHEN NO ONSITE OPERATOR/OWNER.
GAUGES, PIPING – REQUIRED FOR EACH PUMP/FILTER SYSTEM
• One (1) flow meter indicating rate of flow per pump
• One (1) pressure inlet gauge and one (1) pressure outlet gauge per pump.
• One (1) vacuum gauge prior to each pump
• Label circulation piping with function and flow direction