Notes:
4/16/2021 1:40:03 PM
01. POOLS AND SPAS MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH NSPI STANDARDS AND THE CURRENT IRC AS ADOPTED AND AMENDED.
02. DUAL HYDRAULICALLY BALANCED MAIN DRAINS REQUIRED ON EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALL OR FEATURES. MAIN DRAIN COVERS/GRATES MUST BE ANSI/ASME A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED AND MUST HAVE MINIMUM 3 FT SEPARATION BETWEEN INSIDE EDGES OF COVER/GRATE TO COVER/GRATE. ALL SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION.
03. WATER VELOCITY SYSTEMS SHALL BE DESIGNED TO PREVENT WATER VELOCITY IN SUCTION PIPING FROM EXCEEDING 6 FPS (FEET PER SECOND), AND PRESSURE PIPING FROM EXCEEDING 10 FPS. WATER VELOCITY THROUGH SUCTION GRATES/COVERS SHALL NOT EXCEED 1.5 FPS WITH ONE GRATE 100% BLOCKED, OR THE ASME/ANSI A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED GPM (GALLONS PER MINUTE) FLOW RATE WITH ONE COVER 100% BLOCKED.
07. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
08. CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD.
09. OPTIONS NOT PART OF POOL STRUCTURE AS WELL AS PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT
10. EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE LESS THAN 6 HRS.
12. CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
14. STRUCTURES EQUAL AND GREATER THAN 36" IN HEIGHT MUST BE ENGINEERED.
15. PLEASE NOTE: THIS PLACARD DOES NOT INCLUDE ALL REQUIREMENTS.
16. NO ELECTRICAL CONDUCTORS SMALLER THAN NUMBER 12 COPPER ALLOWED.
18. EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALLS AND FEATURES MUST HAVE AN APPROVED ASME/ANSI A112.19.17 SVRS AND BE INSTALLED BY A CERTIFIED INSTALLER TRAINED AND CERTIFIED BY THE MANUFACTURER OF THE DEVICE. THE CERTIFIED INSTALLER SHALL ENSURE THE SVRS DEVICE IS INSTALLED PROPERLY INCLUDING A BALL VALVE ON EACH SYSTEM TO ALLOW THE DEVICE TO BE TESTED. THE CERTIFIED INSTALLER SHALL PROVIDE A SIGNED DOCUMENT CERTIFYING THE APPROVED INSTALLATION OF THE DEVICE AND BALL VALVE.
19. ALL AUTO FILL LINES MUST HAVE RPZ.
23. NO PART OF POOL BEAM OR DECK MAY BE BUILT IN ANY EASEMENT. ANYTHING PLACED IN AN EASEMENT IS SUBJECT TO REMOVAL OR RELOCATION AT HOMEOWNER EXPENSE.
24. ALL OUTLETS THAT SUPPLY POOL PUMP MOTOR(S) AND ARE CONNECTED TO SINGLE PHASE 120-VOLT THROUGH 240-VOLT BRANCH CIRCUITS, WHETHER BY RECEPTACLE OR DIRECT CONNECTION, MUST HAVE GFCI PROTECTION FOR PERSONNEL. IF THE GFCI PROTECTIVE DEVICE FOR THE POOL PUMP REQUIRES ACCESS TO THE RESIDENCE, IT IS THE PERMIT HOLDER'S RESPONSIBILITY TO INFORM THE HOMEOWNER/OCCUPANT TO ALLOW ACCESS BY BUILDING INSPECTION STAFF FOR VERIFICATION OF COMPLIANCE.