Permit Info
Short Description:
390 SF, POOL AND SPA
Notes:
11/9/2021 4:34:47 PM
ENGINEER LETTER ON FILE: We are in receipt of your design for construction of a swimming pool at the above location adjacent to a 3 ft. high gravity stone retaining wall at the rear property line. At nearest point, the pool shell will be set 3’-9” from this wall where maximum depth is approximately 5’-0” at pool center.
Due to the above, we specify a 20 ft. section of the nearest wall be constructed using #4 bars in the beam and twin mats of alternating #4 and #3 rebar at 5x10 in. spacings, while wall thickness in this section should be increased to 14 in. Design of remaining wall sections is understood to use 10-12 in. thick walls with #4 bars in the beam with a single wall grid of alternating #4 and #3 rebar at 5x10 in. spacings. With the above modifications we conclude pool distances from the building will have no adverse effects on the foundation.
--------------------------------------------------------------------------------------------------------------
000 -- POOLS AND SPAS MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH NSPI STANDARDS AND THE CURRENT IRC AS ADOPTED AND AMENDED. -- DUAL HYDRAULICALLY BALANCED MAIN DRAINS REQUIRED ON EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALL OR FEATURES. MAIN DRAIN COVERS/GRATES MUST BE ANSI/ASME A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED AND MUST HAVE MINIMUM 3 FT SEPARATION BETWEEN INSIDE EDGES OF COVER/GRATE TO COVER/GRATE. ALL SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION. -- WATER VELOCITY SYSTEMS SHALL BE DESIGNED TO PREVENT WATER VELOCITY IN SUCTION PIPING FROM EXCEEDING 6 FPS (FEET PER SECOND), AND PRESSURE PIPING FROM EXCEEDING 10 FPS. WATER VELOCITY THROUGH SUCTION GRATES/COVERS SHALL NOT EXCEED 1.5 FPS WITH ONE GRATE 100% BLOCKED, OR THE ASME/ANSI A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED GPM (GALLONS PER MINUTE) FLOW RATE WITH ONE COVER 100% BLOCKED. -- DIVING BOARDS AND SLIDES AND THEIR ASSOCIATED ENVELOPES MUST MEET NATIONAL STANDARDS (NSPI OR CPSC) AND BE INSTALLED PER MANUFACTURER INSTRUCTIONS. STEPS AND HANDRAILS FOR STRUCTURES SUCH AS SLIDES AND BRIDGES MUST COMPLY WITH BUILDING CODES. -- GAS VENT TO TERMINATE MINIMUM 5' HORIZONTAL FROM OPENABLE WINDOW OR 3' MINIMUM ABOVE. -- WINDOWS LESS THAN 5' TO WATER MUST BE TEMPERED/SAFETY GLAZED TO CODE. -- CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION. -- CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD. -- OPTIONS NOT PART OF POOL STRUCTURE AS WELL AS PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT. -- EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE LESS THAN 6 HRS. -- BACKWASH LINE MUST BE INSTALLED AT TIME OF TRAP INSPECTION TO INSURE PROPER AIR GAP. -- CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
Parcel Info
City/State/Zip:
FRISCO, TX, 75068
Subdivision:
ESTATES AT ROCKHILL PHASE III
|
OWNER | MASTER DEVELOPERS-HSB LLC | ()- | | | PLANO, TX 75093 |
APPLICANT | GOLD MEDAL POOLS INC | (972)712-4653 | permits@goldmedalpools.com | 4326 PRESTON RD | FRISCO, TX 75034 |
CONTRACTOR | GOLD MEDAL POOLS INC | (972)712-4653 | permits@goldmedalpools.com | 4326 PRESTON RD | FRISCO, TX 75034 |
ELECT. CTR. | RB ELECTRIC | (972)475-2339 | rbelectricrowlett@yahoo.com | PO BOX 1263 | ROWLETT, TX 75030 |
POOL CONTRAC | GOLD MEDAL POOLS INC | (972)712-4653 | permits@goldmedalpools.com | 4326 PRESTON RD | FRISCO, TX 75034 |
PLUMBING | WATER WORKS PLUMBING | (214)850-2038 | amywaterworksplumbing@gmail.com | 1303 CAPITAL AVE #A | PLANO, TX 75074 |
|
CREDIT CARD FEE |
$6.10
|
11/15/2021
|
POOL - BELOW GROUND W/SPA |
$275.00
|
11/15/2021
|
POOL FEE |
$10.00
|
11/15/2021
|
POOL PLUMBING FEE |
$20.00
|
11/15/2021
|
Total Fees |
Charged: $311.10
Balance Due: $0.00
|
There are currently no inspections on this record.
|
INITIAL REVIEW | TREB DUMA | ACCEPTED | 9/24/2021 | 9/24/2021 | 10/8/2021 |
More Info
|
POOL REVIEW | RYAN KUHLMAN | DENIED | 9/24/2021 | 10/8/2021 | 10/1/2021 |
More Info
|
POOL REVIEW | TINA MOORE | APPD W/ CONDITIONS | 11/9/2021 | 11/9/2021 | |
More Info
|