Notes:
CADD / SHOPS AT STARWOOD PHASE TWO FIREPLACE
10/2/2007 12:00:00 AM
* ALL WORK PERFORMED MUST MEET THE 2003 IRC STANDARDS.
* FIREPLACE MUST BE 100% MASONRY.
* VENTING AND FIREPLACE FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
* MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTIBLE ITEMS.
* PLUMBING PERMIT IS REQ'D. FOR THE GAS LINE TO FIREPLACE
* ALL WORK IS SUBJECT TO FIELD APPROVED INSPECTIONS AND TESTING
* NO ELECTRICAL PERMITTED FOR THIS SUBMITTAL
* CHIMNEYS SHALL EXTEND @ LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10' BUT SHALL NOT BE LESS THAN 3' ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF.
* SEE IRC 2003 T. R1003.1 FOR REQ'MENTS ON INSTALLATION
* MAINTAIN 4' BEHIND FIREPLACE STRUCTURE FOR REQ'D. ACCESSIBILITY.
* FOUNTAIN SHOWN ON PLANS NOT IN SCOPE OF WORK. (THIS HAS BEEN MOVED TO A DIFFERENT LOCATION).